V. BUILDING INFORMATION
School Reference
Building ID
EMIS260030018-E
VI. BUILDING CATEGORY (P0)
Building category
RC: Reinforced concrete
VII. MAIN STRUCTURAL SYSTEM (P1)
Main structural system
RC2: Infilled Frame
VIII. HEIGHT RANGE (P2)
IX. SEISMIC DESIGN LEVEL (P3)
Construction responsible
CR0: No information
Construction responsible : Other (specify)
Presence of seismic enhancement measures
Columns with minimum dimension greater or equal to 30 cm
X. DIAPHRAGM TYPE (P4)
Roof: Type of structure
RC solid slab
Floors: Type of structure
RC solid slab
XI. STRUCTURAL IRREGULARITY (P5)
Horizontal Irregularity: Plan Shape of the building
Rectangular
Vertical Irregularity
None
XII. LBM: WALL PANEL LENGTH, RC: SPAN LENGTH (P6)
Maximum bay length between the columns (meters)
5.58 (m)
XIV. FOUNDATION TYPE (P8)
Foundation structure
Reinforced concrete isolated spread footing
XV. SEISMIC POUNDING RISK (P9)
Minimum building separation (potential pounding risk)
0.00 (m)
XVI. SEISMIC RETROFITTING (P10)
Original Structure (Yes/No)
No
What was the retrofitting intervention?
RC jacketing of columns and other elements;
Year of retrofitting (if retrofitted)
Does the school have seismic pounding risk