V. BUILDING INFORMATION
Building ID
EMIS120360005-C
VI. BUILDING CATEGORY (P0)
Building category
RC: Reinforced concrete
VII. MAIN STRUCTURAL SYSTEM (P1)
Main structural system
RC2: Infilled Frame
VIII. HEIGHT RANGE (P2)
Number of Stories
2
IX. SEISMIC DESIGN LEVEL (P3)
Construction responsible
CR0: No information
Construction responsible : Other (specify)
X. DIAPHRAGM TYPE (P4)
Roof: Type of structure
Timber framed structure without concrete slab
Roof Coverings (Diaphragm type)
Light
Floors: Type of structure
RC solid slab
XI. STRUCTURAL IRREGULARITY (P5)
Horizontal Irregularity: Plan Shape of the building
Rectangular
Vertical Irregularity
Setback irregularity;
XII. LBM: WALL PANEL LENGTH, RC: SPAN LENGTH (P6)
Maximum bay length between the columns (meters)
3.45 (m)
XIV. FOUNDATION TYPE (P8)
Foundation structure
Reinforced concrete combined footing
XV. SEISMIC POUNDING RISK (P9)
Minimum building separation (potential pounding risk)
0.15 (m)
XVI. SEISMIC RETROFITTING (P10)
Original Structure (Yes/No)
Yes
Does the school have seismic pounding risk
Submitted by gpss_admin on