V. BUILDING INFORMATION
Building ID
EMIS200390011-H
VI. BUILDING CATEGORY (P0)
Building category
RC: Reinforced concrete
VII. MAIN STRUCTURAL SYSTEM (P1)
Main structural system
RC2: Infilled Frame
VIII. HEIGHT RANGE (P2)
Number of Stories
2
IX. SEISMIC DESIGN LEVEL (P3)
Construction responsible
CR0: No information
Construction responsible : Other (specify)
X. DIAPHRAGM TYPE (P4)
Roof: Type of structure
RC solid slab
Floors: Type of structure
RC solid slab
Floors: Connection to the lateral load resisting system
Monolithic or embedded
XI. STRUCTURAL IRREGULARITY (P5)
Horizontal Irregularity: Plan Shape of the building
Rectangular
Vertical Irregularity
None
XII. LBM: WALL PANEL LENGTH, RC: SPAN LENGTH (P6)
Maximum bay length between the columns (meters)
4.97 (m)
Wall thickness
0.26
XIV. FOUNDATION TYPE (P8)
Foundation structure
Other (Specify)
Foundation structure : Other (Specify)
N/A
XV. SEISMIC POUNDING RISK (P9)
Minimum building separation (potential pounding risk)
1.00 (m)
XVI. SEISMIC RETROFITTING (P10)
Original Structure (Yes/No)
Yes
Does the school have seismic pounding risk
Submitted by gpss_admin on