V. BUILDING INFORMATION
School Reference
Building ID
EMIS220240018-H
VI. BUILDING CATEGORY (P0)
Building category : Other (specify)
RC: Reinforced concrete
VII. MAIN STRUCTURAL SYSTEM (P1)
Main structural system
RC6: Prefabricated reinforced concrete system
VIII. HEIGHT RANGE (P2)
Number of Stories
1
IX. SEISMIC DESIGN LEVEL (P3)
Building construction year (approx.)
2016
Construction responsible
CR4: Community
Construction responsible : Other (specify)
X. DIAPHRAGM TYPE (P4)
Roof: Type of structure
Steel framed structure without concrete slab
Roof: Connection to the lateral load resisting system
Monolithic or embedded
Roof Coverings (Diaphragm type)
Light
XI. STRUCTURAL IRREGULARITY (P5)
Horizontal Irregularity: Plan Shape of the building
Rectangular
Vertical Irregularity
None
XIV. FOUNDATION TYPE (P8)
Foundation structure
Stonework strip footing
XV. SEISMIC POUNDING RISK (P9)
Minimum building separation (potential pounding risk)
1.00 (m)
XVI. SEISMIC RETROFITTING (P10)
Original Structure (Yes/No)
Yes
XVIII. VULNERABLE NON STRUCTURAL COMPONENTS (P12)
Roof Coverings
Good
Does the school have seismic pounding risk
Submitted by gpss_admin on