V. BUILDING INFORMATION
School Reference
Building ID
EMIS240150003-C
VI. BUILDING CATEGORY (P0)
Building category
LBM: Load bearing masonry
VII. MAIN STRUCTURAL SYSTEM (P1)
Main structural system
UCM-URM2: Rubble Stone in Mud Mortar Masonry
VIII. HEIGHT RANGE (P2)
IX. SEISMIC DESIGN LEVEL (P3)
Construction responsible
Other (Specify)
Construction responsible : Other (specify)
Foreign individual Michael
X. DIAPHRAGM TYPE (P4)
Roof: Type of structure
Timber framed structure without concrete slab
Roof Coverings (Diaphragm type)
Light
XI. STRUCTURAL IRREGULARITY (P5)
Vertical Irregularity
None
XII. LBM: WALL PANEL LENGTH, RC: SPAN LENGTH (P6)
Wall thickness
0.46
XIV. FOUNDATION TYPE (P8)
Foundation structure
Stonework strip footing
XV. SEISMIC POUNDING RISK (P9)
Minimum building separation (potential pounding risk)
1.00 (m)
XVI. SEISMIC RETROFITTING (P10)
Original Structure (Yes/No)
Yes
Does the school have seismic pounding risk