V. BUILDING INFORMATION
School Reference
Building ID
EMIS280330001-B
VI. BUILDING CATEGORY (P0)
Building category
LBM: Load bearing masonry
VII. MAIN STRUCTURAL SYSTEM (P1)
Main structural system
UCM-URM7: Rectangular Block in Cement Mortar Masonry
VIII. HEIGHT RANGE (P2)
Total height (m)
2.80
IX. SEISMIC DESIGN LEVEL (P3)
Construction responsible
Other (Specify)
Construction responsible : Other (specify)
Langtang Foundation
Presence of seismic enhancement measures
Evidence of internal vertical and/or horizontal reinforcement in masonry walls (already a typology i.e. RM)
X. DIAPHRAGM TYPE (P4)
Roof: Type of structure
Timber framed structure without concrete slab
Roof Coverings (Diaphragm type)
Light
XI. STRUCTURAL IRREGULARITY (P5)
Horizontal Irregularity: Plan Shape of the building
Rectangular
Vertical Irregularity
None
XII. LBM: WALL PANEL LENGTH, RC: SPAN LENGTH (P6)
Maximum wall length between adjacent restricted borders
6
Wall thickness
0.23
XIV. FOUNDATION TYPE (P8)
Foundation structure
Other (Specify)
Foundation structure : Other (Specify)
N/A
XV. SEISMIC POUNDING RISK (P9)
Minimum building separation (potential pounding risk)
1.00 (m)
XVI. SEISMIC RETROFITTING (P10)
Original Structure (Yes/No)
Yes
Does the school have seismic pounding risk